• High Quality Power Meter Nk30 Handheld Fiber Optic Light Source Vfl
  • High Quality Power Meter Nk30 Handheld Fiber Optic Light Source Vfl
  • High Quality Power Meter Nk30 Handheld Fiber Optic Light Source Vfl
  • High Quality Power Meter Nk30 Handheld Fiber Optic Light Source Vfl
  • High Quality Power Meter Nk30 Handheld Fiber Optic Light Source Vfl
  • High Quality Power Meter Nk30 Handheld Fiber Optic Light Source Vfl

High Quality Power Meter Nk30 Handheld Fiber Optic Light Source Vfl

Type: Power Meter
Wiring Devices: ODF
Condition: New
Connector Type: FC/PC (Interchangeable Sc, St)
Application: FTTH FTTB FTTX Network
Product Name: Hand-Held FTTH Power Meter
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
NK30
Dimensions
190 *100 *48 or 165*75*28mm
Type Name
Testers &Tools
Specification
w600*d900*h2000mm
Origin
China
HS Code
8517799000
Production Capacity
50000 Per Year

Product Description

Summary
Handheld light power meter series products are mainly used for continuous optical signal power measurement. It adopts single chip microprocessor to control, and has complete functions. Widely used in optical fiber construction and maintenance, optical fiber communication, optical fiber sensing, optical CATV and other fields. The fuselage design Ergonomic requirements, the use of advanced cold molding process, beautiful and durable. The built-in detector allows it to be well protected. With a small shape, optional switch, background light display and automatic shutdown function, ultra wide optical power testing range.
Note: the version of the instruction is subject to change without notice.

Product characteristics
Support linear (mW) and nonlinear index (dB) simultaneous display
Support automatic shutdown
Support on / off background light
Support user self calibration
Support SC, FC interface, ST interface (apolegamy)
Charging unplugged working time 48 hours (apolegamy)
Support portable battery / computer power supply (apolegamy)
Support  wavelength memory function
Support optical fiber work identification

Technical index
Wavelength range 800~1700
Connector FC/SC/ST(ST   apolegamy )
Type of Detector InGaAs
Power measurement range -70~+3  or  -50~+20
Uncertainty ±5%
Standard wavelength (nm) 850,980,1300,1310,1490,1550,1625
Display resolution Linear indication:0.1% Logarithmic indication:0.01dBm
working temperature (ºC) -10~+60
Storage temperature (ºC) -25~+70
Auto off time (min) 10
Battery Working Time  (h) ≥48
Instrument size (mm) 190 *100 *48or165*75*28
Power Supply No. 5 battery *3 or rechargeable lithium battery
weight (g) 300/400

Note:
1,Range of wavelength:  a standard working wavelength that we specified: min-max, the optical power meter within this range can work well with all indicators meeting requirements.
2,Power measurement range:the maximum power that the meter can measure as per required indicators.
3,Uncertainty: the error between the test results and standard test results over a standard optical power .

Button description
1,Turn on / off
Press the button to start within a second, then press the button to turn off the power.
2,AUTO/OFF
Press the key to turn off or turn on the automatic shutdown function, and the upper left corner of the LCD will display the prompt at the same time.
3,ZERO
Press the key to realize the automatic clearing of the optical power meter.
4,LIGHT
Press the key can close or open background light; LCD top left corner can show the hint at the same time.
5,dB
The relative measurement of optical power can be carried out at the corresponding wavelength.
6,
7 ,different wavelength optional (850nm,980nm,1300nm,1310nm,1490nm,1550nm,1625nm) LCD showing at the same time.

Screen display instructions
The tested power are shown with the forms of dB,dBm,mW,uW,nW; there are 7 types to show wavelength.

Calibration function description
At the same time press the "LIGHT" +  button, then enter the user mode, the lower right corner of the screen shows the letter "CAL", the following function is in the combination button pressed after effective.
Function Push-button Comments on a form
Increase 0.05dB dB *1.01158
Reduce 0.05dB LIGHT *0.99855
Preservation ZERO Press the boot button(Store to flash)
Switching wavelength    
Restore factory settings +ZERO Display "FAC", The default value is also read into the array.

Measurement of relative power and absolute power
1,Absolute power
If the 1310nm wavelength is chosen, the screen will show the present value, including linear value of absolute light power and non-linear value when the tested light is connected.
2,Relative power
When the wavelength is set, in the mode of absolute light power, connects the tested light to test the present power value. dB is pressed at this moment and the present power value is reference (dBm is unit). Another tested light is connected and the absolute and relative power are shown.

Standard configuration
The host, light power meter product warranty card, certificate, instructions, Oxford roolls (apolegamy), three 5 dry cell batteries (apolegamy), lithium battery (apolegamy), charger, adapter (apolegamy) (SC and FC standard, ST apolegamy).

Charging function (apolegamy)
Battery indicator does not display the work, when the power is not enough to provide normal work, power index every second flash once, 10 seconds after the automatic shutdown, then do not start again, with the power adapter is equipped with charging after the boot.

Solutions to common faults
Malfunction Tips Cause Solution
LCD monitor weak Insufficient power Charge or change battery
Could not display when starting Lack of power or other Restart machine or charge, change battery
abnormal data display of LCD Adapter fault, dirty or be locked Reconnect adapter and clean sensor

Routine maintenance and maintenance
1,Please keep cleaning of the sensor frequent and there should be no fat, no pollution and not use dirty and not standard adapter. Do not insert the end face of bad polished surface, or it will damage the end face and there will be error in testing.
2,Stick to an adapter as much as possible.
3,Once the machine is unused, please cover the dust cap to keep the end face clean prevent from exposing in the air and prevent from attaching the dust which leads to the wrong measurement .
4,Carefully plug optical adapter connector to avoid port scratches.
5,Clean the sensor surface periodically. When cleaning the sensor surface, wipe it gently in the circumferential direction with a special cleaning swab.

Quality Guarantee
1, Within twelve natural months after the user receives the goods, our company will promise the quality and workmanship of its products. The warranty period is within twelve months from the date of receipt: when the purchased product is found to have quality problems during this period , Our company will make corresponding treatment or replacement, but under any circumstances, our responsibility will not exceed the purchase value of the product.
2,If the instrument has something wrong when using and it is unsolved with the common malfunction solution, users are forbidden to open the shell and contact with our company.
3,  As to the malfunction made by the disadvantage of the product, our company will be in charge of repairing or changing product for free.
Note: the guarantee is only suitable in the normal instrument under the situation of no damage and no wrong operation, our company will repair or change freely if the mistake is made by quality or disadvantage of material. As to accident or improper usage or repair without authorization, our company has right to reject the guarantee.





 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now